Nortel Networks 311 Computer Hardware User Manual


  Open as PDF
of 1134
 
296 NT5D33 and NT5D34 Lineside E1 Interface cards
Figure 65
HELP (H, ?) screen
Each of these commands can be executed by entering the first letter of the
command or by entering the entire command. Commands with more than
one word are entered by entering the first letter of the first word, a space,
and the first letter of the second word or by enter ing the entire command.
Table 124 "MMI commands and command sets" (page 296) shows all
possible MMI commands in alphabetical order. These commands are also
described later in this section.
Table 124
MMI commands and command sets
Command
Description
AD Alarm Disable. Disables all alarms.
AE Alarm Enable. Enables all alarms.
CA
Clear Alarm. Clears all alarms, terminates time processing, and resets the E1
bit error rate and frame slip counters.
CAL
Clear Alarm Log. Clears alarmlog.
CE
Clear Error. Clears the E1 error counter.
D A(P) Display Alarms. Displays the alarm log, which is a list of the 100 most recent
alarms with time and date stamps. (Momentarily stop the scrolling display by
typing P. Continue scrolling by typing any other key.)
D C(P)
Display Configuration. Displays the configuration settings for the LEI(s), single-
or multiple-card system. Display includes each card’s serial number, MMI firmware
version, date and time, alarm disable/enable setting, self-clearing disable/enable
setting, values entered through the Set Configuration command, and dip switch
settings.(Momentarily stop the scrolling display by typing P. Continue scrolling by
typing any other key.)
D H(P) Display History. Displays performance counters for the past 24 hours.
(Momentarily stop the scrolling display by typing P. Continue scrolling by typing
any other key.)
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.