472 NT7D16 Data Access card
complete list of the parameters allowed for each S Register, see Table 184
"Hayes parameters and S register reset values" (page 469) describing the
S Registers.
In the following example, <GT> is the Guard Time and <EC> the Escape
Character defined in the S2 register. The example shows the Off Line
escape sequence, the command to display an S register (Ring Count, in this
case), and the command to go back on line and attend to the answered call.
<GT><EC><EC><EC><GT
OK
ATS1
005
OK
ATO0
CONNECT
Specifications
QPC430 and QPC723 interfaces
The NT7D16 Data Access card provides the same features as the QPC430
four-port Asynchronous Interface Line Card (AILC) and the QPC723
RS-232 Interface Line Card (RILC). The operational mode for each port is
determined in LD 11.
Download parameters
These parameters are configured in the system through service change
operations. They are then downloaded to the DAC. For a complete
description of the service change procedures, see Software Input/Output
Reference Administration (NN43001-611)..
System parameters
System parameters downloaded by the switch include the type of system,
the inactivity timer, and the data DN. These parameters are described below:
System type: CS 1000E, CS 1000M, and Meridian 1
Inactivity timeout
No timeout
15 minutes
30 minutes
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.