Installation and configuration 193
Dip Switch
Number Characteristic Selection
3–6
XPEC Address for the Lineside T1 card See Table 88 "Lineside T1
card - XPEC address dip
switch settings (Switch S1,
positions 3 - 6)" (page 193)
7
Not Used Leave Off
8
Reserved for SL-100 use Leave Off
Table 88
Lineside T1 card - XPEC address dip switch settings (Switch S1, positions 3 - 6)
XPEC
Address
S1 Switch
Position 3
S1 Switch
Position 4
S1 Switch
Position 5
S1 Switch
Position 6
00
Off Off Off Off
01
Off Off Off On
02
Off Off On Off
03
Off Off On On
04
Off On Off Off
05
Off On Off On
06
Off On On Off
07
Off On On On
08
On Off Off Off
09
On Off Off On
10
On Off On Off
11
On Off On On
12
On On Off Off
13
On On Off On
14
On On On Off
15
On On On On
Table 89
Lineside T1 card - T1 Switch 2 (S2) dip switch settings
Dip Switch
Number Characteristic Selection
1
T1 framing On = D4
Off = ESF
2
T1 Coding On = AMI
Off = B8ZS
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.