Nortel Networks 311 Computer Hardware User Manual


  Open as PDF
of 1134
 
72 Acceptance tests
1
Log into the system:
LOGI (password)
2
Request the status of a loop on the conference card:
LD 38
STAT loop
Conference status is formatted as follows:
CNFC n DSBL n BUSY
"n" represents the number of conference groups disabled and busy
CHAN n DSBL n BUSY
"n" represents the number of channels disabled and busy
UNEQ
card is not equipped in the system
DSBL card is disabled in software
3
If the conference card loop is disabled, enable it.
For an NT8D17 Conference/TDS card, enter:
ENLX loop
(the conference loop is the odd loop of the conference/TDS loop pair)
Note: The conference/TDS card is not enabled automatically
when it is inserted. You must enable the card with the command
ENLX. (This command is used in LD 34 and LD 46 to address
even loops and in LD 38 to address odd loops.) Enabling the
loops with the command ENLL does not enable the hardware
for the card.
For other than an NT8D17 Conference/TDS card, enter:
ENLL loop
(the conference loop must be an even loop for cards other than the
NT8D17)
If the system response is other than OK, seeSoftware Input/Output
Reference Administration (NN43001-611) to analyze the
messages.
4
Test the conference loop for channel, group, and switching faults:
CNFC loop
If the conference loop passes the tests, the output is OK.
If the system response is other than OK, see Software Input/Output
Reference Administration (NN43001-611) to analyze the
messages.