Chapter 2 Principles of Operation
2.1.08 Alarm Circuit
Driver Circuit Alarm Processing
The printhead driver output, the head gap magnet output and the color ribbon magnet drive signal
are monitored at R670 and C15, and the POWER OFF-P signal is output by the comparator
(Location 01A: IC2901) when driven for more than the specified time. This signal becomes the
ALM signal. The ALM signal is sent to the power supply board and causes the DC voltages to be
turned off.