Panasonic MDDDT3530 Power Supply User Manual


 
- 49 -
Preparations and Adjustments
CN MOTOR
CN I/F
CN SIG
Set the rotary switch to
default "0" position
for GAIN adjustment.
2.Check LED status.
Make sure that the alarm code LED is not flashing.
(Under the normal operation, the alarm indicator is OFF.)
This indicator will start flashing when an alarm occurs.
Alarm codes (see page 60-65) are indicated by the number of flash
(in orange and red)
Orange: Tens digits, Red: Unit digits
3. Set Parameters.
Prepare a personal computer and PANATERM
®
.
4. Input commands relevant to
the desirable control mode.
LED color
Green
Orange
Red
Meaning
Main power is on. Amplifier power is on.
Flashing when warning occurs. (Overload, excessive regenerative energy)
Alarm
(Example)
When an overload (alarm code No.16) occurs:
The alarm indicator will flash in orange once and in red six times.
orange
1 sec.
red
0.5 sec.
0.5 sec.1 sec.
red
0.5 sec.
red
0.5 sec.
red
0.5 sec.
red
0.5 sec.
red
0.5 sec.
0.5 sec. 0.5 sec. 0.5 sec. 0.5 sec.
After
2
seconds