Power
Single-phase 100V : Single-phase 100 to 115V +10%/-15%, 50/60Hz
Single-phase 200V : Single-phase 200 to 230V +10%/-15%, 50/60Hz
Three-phase 200V : Three-phase 200 to 230V +10%/-15%, 50/60Hz
(1) Use under the environment of Over-voltage Category III specified by IEC60664-1.
(2) The power for interface should be marked CE or appropriate EN Standard type, 12VDC to
24VDC, insulated.
Circuit Breaker
Install a circuit breaker between the power supply and noise filter. The circuit breaker should
be IEC Standard and UL listed marked.
Noise Filter
If several amplifiers are used, and a single noise filter is installed at the power supply, consult
the manufacturer of the noise filter.
Peripheral Equipment
Environment
The servo amplifier should be used under Contamination Level 2 or 1 specified by IEC60664-
1 (housing the amplifier in an IP54 control box).
Control box
Controller
Insulated power
for interface
Power
Circuit
breaker
Surge
absorber
Noise filter
Noise filter for
signal lines
Protective earth (PE)
L1
U
CN–I/F
CN–SIG
M
RE
V
W
E
L2
L3
Noise filter for
signal lines
AC servo
amplifier
AC servo
motor