Recorder Settings
Be sure to perform the settings for connected recorders in
SETUP MENU of recorders.
You can set
w to t before starting operation. However,
you must set
q separately for each recorder before con-
nections. The settings are performed in SETUP MENU
(Advanced).
q Unit Address (System)
Set the Unit Address (System) for each recorder in
"Comm" – "PS.Data Setup". 001 to 016 are available.
(Up to 16 recorders can be connected.) The unit
address setting must be different each other.
w Unit Address (Controller)
Set the Unit Address (Controller) for each recorder in
"Comm" – "PS.Data Setup". 001 to 004 are available.
(Up to 4 recorders can be connected to a DATA port.)
The unit address setting must be different each other.
e Camera Number Setup
Perform the Camera Number Setting for each recorder
in "Comm" – "PS.Data Setup. The camera number set-
tings must be identical as the LCN settings of this unit.
Example: To supply video input signal from Camera 999 to
the CAMERA IN 16 connector of Recorder 16 (Unit
Address (System): 16), select CAM NO. 999 for CAM
PORT 16.
r Camera Control
Select PSD for CAM1 to CAM16 in "Comm" – "Camera
Control".
t Event REC
To activate alarm recording, perform the event record-
ing settings surely. Refer to the operating instructions of
recorders for details.
Maintain the factory default for the following settings.
PSD User setting in "System" – "Basic Setup": ADMIN
Operation Mode setting of each Event Program – VMD,
VIDEO LOSS, and Terminal/Command Alarm in
"Schedule" – "Event Program": ALARM
(When setting QUICK for REC Type, Operation Mode
setting of Event REC in "SETUP MENU (Quick)" – "REC
& Event": ALARM)
Settings in "Comm" – "PS.Data Setup" of SETUP MENU,
except for
q to e.
System Controller Connection
The following is a connection example to use system con-
trollers.
There are two options to connect system controllers to this
unit.
Terminal mode: Normally, this operation mode is
applied.
PS·Data mode: When other system units are connected
to this unit, and they are controlled by the same system
controller, this operation mode is applied. This mode
has operation restrictions. Refer to p. 48 OPERATION
(OTHER THAN TERMINAL MODE.
Terminal Mode Connection
To apply the terminal mode, connect the system controllers
as follows.
1. Connect the system controllers to the DATA 1 to 4 ports
of the unit.
Notes:
•In the factory default, the DATA 3 and 4 ports are
set to HDR1 for recorder connection. To connect
system controllers, perform the DATA port settings
in SETUP MENU (refer to p. 90) or WJ-SX650 Series
Administrator Console.
Both of recorders and system controllers cannot be
connected to the same DATA port.
•By connecting up to 4 system controllers to one
DATA port in the daisy chain, up to 16 system con-
trollers are available in the system. (However, up to
16 system controllers can log into the system at a
time.)
•Daisy chain connection is available with System
Controller WV-CU950/650 (Ver. 2.00 or later).
2. Set the system controllers to the terminal mode. (Refer
to the operating instructions of system controllers.)
3. Set the CONTROLLER NO. switches of system con-
trollers to 1. (In the daisy chain connection, set 1 to 4
for each controller. The switch setting must be different
from each other. However, when connecting system
controllers to different DATA ports, you can use over-
lapped controller numbers.)
Note: Refer to the operating instructions of system con-
troller for details on the CONTROLLER NO. switch
setting.