Panasonic WJ-SX650 Switch User Manual


 
85
• Recorder control
When using WV-CU360C/CJ, refer to the operating instruc-
tions of recorder.
• Alarm
Alarm ACK, alarm individual reset, and alarm monitor reset
are not available. (Alarm all reset is available.) When con-
trolling Alarm History Display from WV-CU360C/CJ, you
cannot skip to 10 pages forward or backward. (Refer to p.
39.)
• Error message display
When you fail in operations, error messages (Not Avail and
Prohibited) will not be displayed on the LCD (or LED).
You cannot control the following functions by pressing the
associated buttons on system controllers. Control them by
entering the system function numbers. (When using WV-
CU950/650, you can specify the system functions marked
with "*" either by pressing the numeric buttons or recalling
the menu functions on the LCD.)
• WV-CU950/650
1. Enter the system function number by pressing the
numeric buttons.
2. Press the SYS FUNC*
1
(or FUNCTION*
2
) button while
holding down the SHIFT button.
*
1
WV-CU950/650
*
2
WV-CU360C/CJ
System function System function number
Monitor lock ON/OFF* 101
System status display ON/OFF 102
Time and date information* 104
Camera information ON/OFF* 105
Event information* 106
Monitor status ON/OFF* 107
All home positions ON/OFF 120
All auxiliaries ON/OFF 121
This chapter includes notifications on operations from sys-
tem controllers in the PS·Data mode, a web browser
accessing the recorder, or a PC.
PS·Data Mode Operations
Note: When using a system controller in the PS·Data mode,
check the software version.
The available software versions are as follows.
WV-CU950/650: Ver. 2.00 or later
WV-CU360C/CJ: Ver. 8.10 or later
The following is the restrictions of PS·Data mode opera-
tions. Refer to the operating instructions of system con-
troller for details.
• Login
Log into the system by entering the user ID and password
registered in the system controller. After login, you can
control the unit as a PS·Data operator. PS·Data operator
setting is performed in "Operator" – "Operator" of WJ-SX650
Series Administrator Console.
• Logout
Auto logout is not available. Log out from the system manu-
ally.
• Camera selection
When using WV-CU360C/CJ, you cannot select Camera
200 or greater.
• Camera position
When using WV-CU950/650, camera positions registered in
the system controller are activated. (Up to 999 camera
positions are available.) This function is not available with
WV-CU360C/CJ.
• Camera selection recall
Camera selection steps are memorized in the system con-
troller. (Even when you select another monitor, the memo-
rized steps are not cleared.) This function is not available
with WV-CU360C/CJ.
• Preset
When using WV-CU360C/CJ, you cannot select Preset
Position 065 or greater.
• Recorder selection
You cannot select a recorder by entering the recorder num-
ber. To select the recorder, enter the logical camera num-
ber associated with the camera input channel connected to
the recorder.
OPERATION (OTHER THAN TERMINAL MODE)