66
ALARM DESCRIPTIONS
■ Alarm Occurrence
When this unit accept an alarm input signal (terminal alarm, camera alarm, recorder alarm, serial alarm, or video loss), an
alarm event (tour sequence, etc.) is activated automatically. Each alarm input signal is associated with an alarm event setting.
(The setting activates the alarm input signal and alarm event.) Up to 1 024 alarm event settings are available. The alarm event
setting is performed in "Alarm" – "Alarm Event" of WJ-SX650 Series Administrator Console.
By performing the settings of "Alarm Event", the following events will be activated when this unit accepts an alarm input signal.
•Alarm event information will be displayed on the associated monitors (Refer to p. 16 Monitor Display Information.)
• Depending on the setting of "Display Mode", camera images will be displayed, or sequences will be activated on the asso-
ciated monitors. In this document, these actions are mentioned as the alarm mode, and pictures displayed during the
alarm mode is mentioned as alarm pictures.
• If a recorder is selected for "Recording Source LCN", event recording will be activated. (Recording will follow the command
alarm setting and event recording setting of recorder. Refer to the operating instructions of recorder for details.)
• If an alarm output terminal is selected for "Alarm Output", alarm output signal will be supplied from the video output board.
The associated recorder can be notified of the alarm occurrence, and external alarm devices (buzzer, etc.) can be activat-
ed.
Notes:
• To activate terminal alarm output signals, perform settings of No.1 to 64. No.65 and greater are assigned for serial
commands.
• To activate serial alarm output signals, serial command settings are required. The settings are performed in
"Communication" – "Serial Command" of WJ-SX650 Series Administrator Console.
•ALARM indicators of all system controllers blink.
•Up to 10 000 alarm records are saved chronologically. The latest 1 000 alarm records can be displayed as the alarm his-
tory on the monitor. (Refer to p. 33 Alarm History Display.) The Alarm History Display can be downloaded from the PC to
the unit.
•Alarm information is notified to the PC in serial commands. The serial command setting is performed in "Communication" –
"Serial Command" of WJ-SX650 Series Administrator Console.
Terminal alarm setting
N
o
.
1
1
(
D
i
s
h
)
N
o
.
1
0
(
P
o
t
)
No.1 (Entrance)
Sensor
system
Alarm Input 256
Matrix Switcher WJ-SX 650
650
Alarm input signal
from a sensor
ALARM
TIMER
HDD 2
ERROR
HDD 1
ALARM
SUSPEND
ALARM
RESET
OPERATE
MONITOR1
MONITOR2
1
5
9
13
2
6
10/0
14
3
7
11
15
4
8
12
16
SEQSHIFT OSD
PAN/
TILT
STOP
PLAYPAUS E
REC
-
REC STOP
ZOOM/
FOCUS
TEXT
COPY
DISK SELECT
EL-ZOOM
MARK
LOGOUT
IRIS
PRESET
/AUTO
A-B
REPEAT
GOTO
LAST
LISTED
SEARCH
BUSY
SETUP
/ESC
SET
REV
—+
FWD
PULL
Digital Disk Recorder
WJ-HD
PAN/TILT
SLOW
Infrared sensor
Preset Position 1
(Zooming in No.1 (Entrance))
Monitor 5
Terminal Alarm
256
This unit
Camera 100
PC
Alarm Output 50
Recorder 10
Records the image
of Camera 10.
(Recording follows
the command alarm
setting and event
recording setting of
recorder.)
Notifies the
alarm event
occurrence.
No. Display Mode
Spot
Monitor
Recording
Source (LCN)
Alarm Output
LCN Preset
256 SPOT 100 1 5 10 50