55
LOGIN AND LOGOUT
■ Operator Registration
Before logging into the system, operator registration is required. Operator registration is performed in "Operator" – "Operator" of
WJ-SX650 Series Administrator Console. The factory default of operator information is as follows.
•
Operator No.: Number given for operator registration.
Up to 59 operators can be registered.
• User ID: ID number of operator controlling this unit. 1 to
99998 are available.
Note: Begin the entry with a numeric other than "0".
•
Password: For login, a password is checked as well as
a User ID. Up to 5 digits are available.
Note: To protect system controllers from misuse, be
sure to change the factory default passwords.
• Level: An operator's restrict level. 1 to 5 are available. 1
is the highest, and 5 is the lowest.
Note: Desired functions can be assigned to each level
in "Operator" – "Level Table" of WJ-SX650 Series
Administrator Console.
•
Priority: Operator priority given to control a monitor,
camera, or recorder selected by another operator. 1 to
99 are available. 1 is the highest, and 99 is the lowest.
•
Camera Access: View and control can be enabled or
disabled for each camera.
VIEW & OPERATE: An operator can display the select-
ed camera image on the selected monitor. The
operator can also control the camera.
VIEW: An operator can display the selected camera
image on the selected monitor, but cannot control
the camera.
- -: The operator can neither display the selected cam-
era image on the selected monitor nor control the
camera.
•
Recorder Access: View and control can be enabled or
disabled for each recorder.
VIEW & OPERATE: An operator can display the select-
ed recorder image on the selected monitor. The
operator can also control the recorder.
VIEW: An operator can display the selected recorder
image on the selected monitor, but cannot control
the recorder.
- -: The operator can neither display the selected
recorder image on the selected monitor nor control
the recorder.
•
Monitor Access: Control can be enabled or disabled
for each monitor.
Notes:
•Monitor Access is set for each DATA port.
Operators logging into the system from the same
DATA port have the common setting.
•Monitor Access setting is not applied for operators
logging into the system from the PC connected to
the SERIAL port.
•Monitor Access setting is performed in "Controller" –
"Monitor Access" of WJ-SX650 Series Administrator
Console.
Operator No.
1 650 650 1 1 View & Operate
(All cameras)
View & Operate
(All recorders)
2112345 1 1 View & Operate
(All cameras)
View & Operate
(All recorders)
3 100 100 2 5 View & Operate
(All cameras)
View & Operate
(All recorders)
4 101 101 3 10 View & Operate
(All cameras)
View & Operate
(All recorders)
5 102 102 4 30 View & Operate
(All cameras)
View & Operate
(All recorders)
6 103 103 5 50 View & Operate
(All cameras)
View & Operate
(All recorders)
User ID Password Level Priority Camera Access Recorder Access