WV-CU360C/CJ
q Monitor number
01 to 32: Monitor number
w Camera/recorder/sequence number
001 to 999: Camera number
H01 to 16: Recorder number
t01 to 32: Tour sequence number
r01 to r08: Group sequence number
Note: During sequence pause, "P" is displayed instead
of "t" and "r".
r09 to 32: Group preset number
Note: This sign disappears when you control a camera.
e Event
The following signs appear to indicate events on the
LCD.
A0001 to 0256 (Blinking): Terminal alarm
A0001 to 0999 (Blinking): Camera alarm
A0001 to 0999 (Blinking): Recorder alarm
A0001 to 1024 (Blinking): Serial alarm
A0001 to 0999 (Blinking): Video loss
Note: During the alarm acknowledgement (ACK) status
(refer to p. 31), these signs change to steady light.
Pt000 to 256 (Lighting for 3.0 seconds): Preset position
Note: Pre000 is the home position.
Pr001 to 256 (Lighting for 3.0 seconds): Preset position
is registered.
r Indicators
When the MONITOR and BUSY indicators are light-
ing:
A selected monitor is controlled by a higher-
level user. (Monitor busy)
Note: You cannot control the selected monitor, camera,
and recorder.
When the CAMERA and BUSY indicators are light-
ing:
A selected camera or recorder is controlled by
a higher-level user. (Camera/Recorder busy)
Note: You cannot control the selected camera or
recorder.
When the PROHIBITED indicator is lighting:
You have entered a wrong value.
You have tried to activate a group sequence or
group preset on a monitor not assigned.
You have tried an operation restricted by the level
setting.
qw
r
BUSY PROHIBITED
MONITOR CAMERA