Panasonic WJ-SX650 Switch User Manual


 
91
Check item and remedy Reference
Problem
Cannot control a recorder.
"RECORDER ERROR" is dis-
played on the monitor, and
recorder control is unavail-
able.
During sequence, black
screen and "NOT
ASSIGNED" are displayed on
the monitor.
Auxiliary control does not
become OFF even after the
sequence, timer event, or
alarm event ends.
Timer event or camera event
is not activated.
• Check the LCD (or LED) display or indicators of system con-
troller. When "Busy (or BUSY)" is blinking (or lighting),
recorder control is not available.
17, 18
• Depending on the recorder status, response may be delayed.
Check the status and retry the control.
• Did you control the recorder on the recorder front panel?
Soon after that, control from system controllers may become
unavailable. Wait for a moment and retry the control.
• Check if Monitor 2 is selected with the MONITOR1/MONI-
TOR2 button of recorder. (Refer to the operating instructions
of recorder for details.)
• As the unit is connected to the MONITOR OUT 2 connector
of recorder, do not select Monitor 1 with the
MONITOR1/MONITOR2 button of recorder. When you have
selected Monitor 1, perform an operation that is available for
Monitor 2 only (playback, etc.). Monitor 2 will be selected
automatically.
• Check the connection and settings between the recorder and
the unit.
• Check if the recorders version is correct.
WJ-HD300 Series: Ver. 1.61 or later
WJ-HD300A Series: Ver. 3.10 or later
Check if the sequence setting contains LCN's not registered.
• If the sequence, timer event, or alarm event has turned on
the auxiliary control, the auxiliary control does not become
OFF automatically. Turn off the auxiliary devices manually, or
set an event that turns off the auxiliary control.
• If the timer event or camera event is set to be activated at the
start time of the summer time (daylight saving time), the
event will not be activated.
• If the setting data is uploaded after the start time, the event
will not be activated.
• Timer event will not be activated when monitors are selected
by operators with higher priority than the timer event, display-
ing SETUP MENU, or being in the alarm mode.
63
63
26
23
34, 35, 85
34, 35
34