Philips 5900 Printer User Manual


 
Management and Configuration
102 AXIS 5900 User’s Manual
Follow the instructions below to add a string after the print job:
1. From the print server’s internal Web page, select Admin | Logical Printer
Settings.
2. Select the Printer5 tab.
3. Enter the string 04 in the String After Print Job text field.
4. Click the OK button.
Example:
Follow the instructions below to add strings before and after the print job:
1. From the print server’s internal Web page, select Admin | Logical Printer
Settings.
2. Select the Printer4 tab.
3. Enter the string 1B 26 6C 34 48 in the String Before Print Job text field.
4. Enter the string 1B 26 6C 31 48 in the String After Print Job text field.
5. Click the OK button.
String Substitutions The string substitution function performs search and replace operations
on the print data. The primary application is to replace printer control
commands. Up to twenty string substitutions may be specified
individually for each logical printer.
All strings must be entered as hexadecimal byte values, and each match
and substitute string must be preceded by a count byte.
You substitute command strings by editing the String Substitutions
(PRx_STR) parameter.
Example:
Follow the instructions below to substitute command strings:
1. From the print server’s internal Web page, select Admin | Logical Printer
Settings.
2. Select the PR1 Webeb page.
3. Enter the string 01 0A 02 0D 0A in the String Substitutions text field.
You have an HP LaserJet printer with dual input bins, and want to print on
pre-printed forms when using the logical printer PR4. The standard forms are
taken from bin 1, and the pre-printed forms are taken from bin 2. The string
before print job should contain the command to select bin 2,
E
C
l4H (hex 1B
26 6C 34 48
), and the string after print job should contain the command to
select bin 1,
E
C
l1H (hex 1B 26 6C 31 48).
Assume that you want to replace the UNIX New Line (hex 0A) with an ASCII
NewLine (hex
0D 0A) for logical printer PR1.