6–47Programming
Line Spacing 1/6 Inch
ASCII Hex Decimal
P–Series SFCC LPI;n
SFCC 2
SFCC 32 SFCC 50
Serial ESC 2
1B 32
27 50
Purpose
Sets line spacing to 6 lpi or as set by ESC A.
Comment The
value of
n
can only be 6
or 8. In P–Series protocol and LPI mode, if
n
= 6, this
command
sets line spacing to 1/6 inch. V
alues of
n
other than 6 or 8 cause an error
message (Command Line Error Messages are listed on page 6–3).
SFCC/ESC
2 asserts n/72–inch line spacing as set by SFCC/ESC A (page 6–51). If
no
distance has been set by SFCC/ESC A, the distance is 1/6 inch.
The
control code line spacing selection overrides the control panel
line spacing set
-
ting.
Example The
following example illustrates 1/6–inch line spacing
and assumes that a distance
has
not been set by ESC A.