Printronix P3000 Series Printer User Manual


 
Interfaces78
Remove Controller Board and Install Terminating Resistors
To
install the alternate terminating resistors, perform the following steps and refer to page Figure 73.
1. Loosen three screws from the rear of the EMI shield cover (A). Remove EMI shield cover.
2. Firmly
grasp the Controller board (B) and lift it straight up to unseat the connectors at the printer
base.
3. Open the latches on connector P4 (C) and disconnect the J4 connector (D).
4. Remove the 1K ohm resistor pack from the socket at location 20D on the Controller board.
5. Plug the 220 ohm resistor pack into the socket at location 20D.
6. Plug the 330 ohm resistor pack into the socket at location 20E.
7. Connect connector J4 (D) and close the latches on connector P4 (C).
8. Position
the Controller board (B) in the printer base. Do
not
seat Controller board into base con
-
nectors.
CAUTION
Do
not use Mechanism Driver heat sink as a handle
when r
emoving or installing the
Mechanism Driver board. Damage may result.
VORSICHT
Das Wärmeschild des Steuergliedes für deu Mechanismus nicht als Handgriff
benützen, wenn das PCBA Mechanismus Steuerglied ein oder ausgebaut wird.
Schaden könnte entstehen.
9. Position
the I/O cable (F) between the Mechanism Driver board (E) and the Controller board (B).
10. Install the controller board (B) onto printer base connectors.
11. Install the EMI shield cover (A) and tighten the three screws.