14 – Command Reference
Set Log
14-86 59183-02 A
S
Set Log
Specifies the events to record in the event log and display on the screen. You
determine what events to record in the switch event log using the Component,
Level, and Port keywords. You determine what events are automatically displayed
on the screen using the Display keyword. Alarms are always displayed on the
screen.
Authority Admin session
Syntax set log
archive
clear
component [filter_list]
display [filter]
level [filter]
port [port_list]
restore
save
start (default)
stop
Keywords archive
Collects all log entries and stores the result in new file named logfile that is
maintained in switch memory where it can be downloaded using FTP. To
download logfile, open an FTP session, log in with account name/password of
“images” for both, and type “get logfile”.
clear
Clears all log entries.
component [filter_list]
Specifies one or more components given by [filter_list] to monitor for events. A
component is a firmware module that is responsible for a particular portion of
switch operation. Use a <space> to delimit values in the list. [filter_list] can be one
or more of the following:
All
Monitors all components. To maintain optimal switch performance, do not
use this setting with the Level keyword set to Info.
Eport
Monitors all E_Ports.