Q-Logic 5000 Switch User Manual


 
6 – Port Configuration
Displaying Port Information
6-6 59183-02 A
S
6.1.5
Transceiver Information
Enter the Show Media command to display operational information about one or
more transceivers as shown in the following example. Refer to Table 14-29 for a
description of the transceiver information in the Show Media display.
SANbox #> show media 4
Port Number: 4
-------------
MediaType 400-M5-SN-I
MediaVendor FINISAR CORP.
MediaPartNumber FTRJ8524P2BNL
MediaRevision A
MediaSerialNumber P6G22RL
MediaSpeeds 1Gb/s, 2Gb/s, 4Gb/s
Temp Voltage Tx Bias Tx Pwr Rx Pwr
(C) (V) (mA) (mW) (mW)
----------- ----------- ------------ ----------- -----------
Value 37.32 3.33 7.30 0.373 0.000
Status Normal HighWarning Normal Normal LowAlarm
HighAlarm 95.00 3.90 17.00 0.637 1.264
HighWarning 90.00 3.70 14.00 0.637 0.791
LowWarning -20.00 2.90 2.00 0.082 0.028
LowAlarm -25.00 2.70 1.00 0.073 0.019
NOTE:
The Show Media command requires the SANdoctor license key. To
purchase a license key, contact your authorized maintenance provider or
authorized reseller.