Q-Logic 5000 Switch User Manual


 
14 – Command Reference
Set Log
14-88 59183-02 A
S
None
Specifies no severity levels for display on the screen.
level [filter]
Specifies the severity level given by [filter] to use in monitoring and logging events
for the specified components or ports. [filter] can be one of the following values:
Critical
Monitors critical events. The critical level describes events that are generally
disruptive to the administration or operation of the fabric, but require no
action. This is the default severity level.
Warn
Monitors warning and critical events. The warning level describes events
that are generally not disruptive to the administration or operation of the
fabric, but are more important than the informative level events.
Info
Monitors informative, warning, and critical events. The informative level
describes routine events associated with a normal fabric.
None
Monitors none of the severity levels.
port [port_list]
Specifies one or more ports to monitor for events. Choose one of the following
values:
[port_list]
Specifies the port or ports to monitor. [port_list] can be a set of port numbers
and ranges delimited by spaces. For example, [0 2 10-15] specifies ports 0,
2, 10, 11, 12, 13, 14, and 15.
All
Specifies all ports.
None
Disables monitoring on all ports.
NOTE:
Logging events at the Info severity level can deplete switch resources
because of the high volume of events.