5 – Managing Ports
Displaying Port Information
59022-03 D 5-5
Logout Count Number of logouts that have occurred on the switch.
Al Init Count Number of times the port entered the initialization state.
Invalid Destination
Address
Number of address identifiers (S_ID, D_ID) found to be in
error.
Total LIP Received Number of loop initialization primative frames received.
LIP F7F7 Count A loop initialization primative frame used to acquire an AL_PA.
LIP F8F7 Count Currently not used.
LIP F7AIPs Count This LIP is used to reinitialize the loop. An L_port, identified by
AL_PS, may have noticed a performance degradation and is
trying to restore the loop.
LIP F8AIPs Count This LIP denotes a loop failure detected by the L_port
identified by AL_PS.
LIP AIPdAIPs Count Number of F7, AL_PS LIPs, or AL_PD (vendor specific) resets,
performed.
Class 2 In Frames Number of class 2 frames received by this port.
Class 2 Out Frames Number of class 2 frames transmitted by this port.
Class 2 Words In Number of class 2 words received by this port.
Class 2 Words Out Number of class 2 words transmitted by this port.
Class 3 In Frames Number of class 3 frames received by this port.
Class 3 Out Frames Number of class 3 frames transmitted by this port.
Class 3 Words In Number of class 3 words received by this port.
Class 3 Words Out Number of class 3 words transmitted by this port.
Decode Error Count Number of invalid transmission words detected during
decoding. Decoding is from the 10-bit characters and special K
characters.
Loss Of Sync Count Number of synchronization losses (>100 ms) detected by this
port. A loss of synchronization is detected by receipt of an
invalid transmission word.
Invalid CRC Count Number of invalid Cyclic Redundancy Check (CRC) frames
detected.
Tx Wait Count Number of times the port entered a wait state because it was
out of buffer-to-buffer credits.
Table 5-5. Port Statistics Data Window Entries (Continued)
Entry Description