Q-Logic 59022-03 D Switch User Manual


 
5 Managing Ports
Testing Ports
59022-03 D 5-13
5.2.8
Resetting a Port
The Reset Port option reinitializes the port using configuration parameters in
memory. To reset a port, do the following:
1. In the Faceplate Display, select the port(s) to be reset.
2. Open the Port menu and select Reset Port.
5.3
Testing Ports
The port loopback tests verify correct port operation by sending a frame out
through the loop, and then verifying that the frame received matches the frame
that was sent. Only one port can be tested at a time for each type of test. The
three types of port loopback tests are:
SerDes level (Internal) - The SerDes level test verifies port circuitry. The
SerDes level test sends a test frame from the ASIC through the SerDes chip
and back to the ASIC for the selected ports. The port passes the test if the
frame that was sent by the ASIC matches the test frame that was received.
SFP level (External) - The SFP level test also verifies port circuitry. The
SFP level test sends a test frame from the ASIC through the SerDes chip,
through the SFP transceiver fitted with a loopback plug, and back to the
ASIC for the selected ports. The port passes the test if the test frame that
was sent by the ASIC matches the test frame that was received.
Node-to-Node (Online) - The Node-to-Node test verifies communications
between the port and its device node or device loop. The port being tested
must be online and connected to a remote device. The port passes the test if
the test frame that was sent matches the test frame that was received.
Figure 5-4. Port Loopback Test Window