Star Micronics XR-1000 Printer User Manual


 
Any other values of cn> are invalid and will be ignored. The special characters
affecting each symbol set are given in Chapter 9.
1 Print continuously from the Ail Characters Chart
IBM 1
<ES0
\
1Bh 5Ch
27 92
The command above allows a series of special characters to be printed from the
control code area (OOh thru Wh), where the two parameters give the total number of
characters to be printed (low byte first). On receipt of this command, any codes
received in the range OOh through 1Fh will not be interpreted as control codes, but
will print the characters corresponding to those codes. This will continue for the
number of characters designated by uro> and al>.
1 Print a single character from the Ail Character Chart IBM
1
cESC>
A
1Bh
5Eh
The command above prints a single character from the All Characters Chart. There
arenoparameters.IfthenextcharactertobeprintedhasacodebetweenOOhandlFh,
it will not be treated as a control code, and the character corresponding to this code
will be primed.
1 Select/cancel undefined control code area
Standard 1
1 cESC>
I
en>
I
1Bh
49h
27 73
Cn>
<n>
This command selects the printablecode areaexpansion, where <n> may be a binary
valueofOOh orOlh,oreitherof theASCI1 characters”O”or “1” (30h or 31h). If <n>
is equal to OOh or “0”. then the undefined control code area remains as non-printable
codes. If en> is equl to Olh or “1”. those area shifts to the printable characters.