Tektronix TDS 600B Graphics Tablet User Manual


 
Appendix B: Algorithms
TDS 500C, TDS 600B, & TDS 700C User Manual
B–9
High
HighRef
LowRef
Low
TLFTHF
Fall Time
Figure B–2: Fall Time
3. From THF, continue the search, looking for a crossing of LowRef. Update
THF if subsequent HighRef crossings are found. When a LowRef crossing is
found, it becomes TLF. (Use linear interpolation if necessary.)
4. FallTime = TLFTHF
Timing measurement. The reciprocal of the period. Measured in Hertz (Hz)
where 1 Hz = 1 cycle per second.
If Period = 0 or is otherwise bad, return an error.
Frequency = 1/Period
100% (highest) voltage reference value. (See High, Low on page B–1.)
Using the min-max measurement technique:
High = Max
Frequency
High