Toshiba 310 Copier User Manual


 
FC-210/310 ADJUSTMENT 2 - 20 February 2002 © TOSHIBA TEC
(e) Image location adjustment of primary-scanning direction (Scanner section)
1. While pressing the digital keys [0] and [5] simultaneously, turn the power ON. (Adjustment mode)
2. Place Test Chart No. TCC-1 on the original glass (with the arrow positioned at the left rear side).
3. Press [ENERGY SAVER] [START] to make a copy in the mode of A4/LT, 100%, full color and text/
photo.
4. Measure the distance C from the left paper edge to the 5 mm line of left grid pattern on the copy with a
ruler.
5. Check if the distance C is within a range of 5±0.5 mm or not.
6. If it is not, change values using the following procedure, and repeat step 3. to 5. above.
<Procedure> (Adjustment mode) (Enter code [106] with digital keys) [START]
(Enter a value (acceptable values : 5 to 251) with digital keys)
[SET] or [INTERRUPT] (Stored in memory)
*The larger the adjustment value, the shorter the distance C becomes (0.042 mm/step).
7. When the distance C is within the acceptable range, perform the following procedure.
<Procedure> (Adjustment mode) (Enter code [108] with digital keys) [START]
(Enter a value with digital keys, deducting 47 from the value set in the 05-106 )
[SET] or [INTERRUPT] (Stored in memory)
(f) Image location adjustment of secondary-scanning direction (Scanner section)
1. While pressing the digital keys [0] and [5] simultaneously, turn the power ON. (Adjustment mode)
2. Place Test Chart No. TCC-1 on the original glass (with the arrow positioned at the left rear side).
3. Press [ENERGY SAVER] [START] to make a copy in the mode of A4/LT, 100%, full color and text/
photo.
4. Measure the distance D from the top paper edge to the 10 mm line of top grid pattern on the copy with
a ruler.
5. Check if the distance D is within a range of 10±0.5 mm or not.
6. If it is not, change values using the following procedure, and repeat step 3. to 5. above.
<Procedure> (Adjustment mode) (Enter code [105] with digital keys) [START]
(Enter a value (acceptable values : 85 to 171) with digital keys)
[SET] or [INTERRUPT] (Stored in memory)
*The larger the adjustment value, the longer the distance D becomes (0.12 mm/step).