MJ-1103/1104 © 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
6 - 14
Is the harness between the saddle unit opening/closing switch (SW5) and the CN13 of the sad-
dle control PC board (SDL) or the CN2 of the interface PC board (I/F) disconnected or open cir-
cuited?
l
YES • Reconnect the connector securely if there is any disconnection.
• Replace the harness if open circuited.
NO
1. Replace the finisher control PC board (FIN).
2. Replace the interface PC board (I/F).