Toshiba TECRA S3 Laptop User Manual


 
Tests and Diagnostics
TOSHIBA RAID / RAID Information Display Rev xx.xx.xxxx
Copyright(c) 2005 TOSHIBA CORPORATION. All Rights Reserved.
Level Status Capacity
LD0 RAID-0 OPTIMAL xxGB
Write cache : Enable
MBR Protection : Disable
S.M.A.R.T : Enable
LD1 RAID-0 OPTIMAL xxGB
Write cache : Enable
MBR Protection : Disable
S.M.A.R.T : Enable
Port Assgn Status Size Model Rev
0 LD0-0 ONLINE xxGB FUJITSU-------------- xxxxxxx
1 LD0-0 ONLINE xxGB FUJITSU-------------- xxxxxxx
< RAID : RAID-0 >
3.3.2.3 RAID-0 (2)
When there is one LD and “RAID-0 Critical” is displayed in the shown below, it is
judged that the RAID is configured by two drives.
Level Status Capacity
LD0 RAID-0 Critical xxGB
Stripe Size : 64KB
Write cache : Enable
MBR Protection : Disable
S.M.A.R.T : Enable
Port Assgn Status Size Model Rev
0 LD0-0 ONLINE xxGB FUJITSU-------------- xxxxxxx
1 NODRIVE
< RAID : not OPTIMAL >
3-12 [CONFIDENTIAL] TECRA S3 Maintenance Manual (960-532)
3.3.3 Specification of the failed HDD
Check the RAID configuration condition from the shown below and specify a
failed drive.