10. Stick the protection cover G (B), protection cover SC (A) and two fixing tapes (C)
and (D).
(A)
(B)
(C)
(D)
0 to 1
0 to 1
Fit the cover according to
the outline of the screw.
0 to 1 mm
Do not make the tape over the top of the module.
The tape MUST NOT appear on the display.
Stick the tape according to the outline of the LCD module. Make
sure the tape does not appear on the side of the module.
Figure 4-87 Replacing Sharp fluorescent lamp (XGA) (23)
TECRA S3 Maintenance Manual (960-532) [CONFIDENTIAL] 4-105