4.30.2 Replacing the 15.0-inch XGA Sharp Fluorescent Lamp
CAUTION: When replacing the fluorescent lamp, wear finger covers or gloves to avoid
contaminating or damaging the LCD panel. Be careful not to let dust or
other foreign substance into the module.
Removing the 15.0-inch XGA Sharp fluorescent lamp
To remove the 15.0-inch XGA Sharp Fluorescent Lamp, follow the steps below and refer to
Figures 4-65 to 4-74.
1. Turn the LCD module face down, and remove the protection cover SC (A), protection
cover G (B) and two fixing tapes (C) and (D).
CAUTION: 1) Be careful not to damage the TCP and chip.
2) Discard the tapes(A, C, D) removed.
3) The protection cover G (B) is reused. Do not peel off the place sticked to
the bezel.
(A)
(B)
(C)
(D)
Figure 4-65 Replacing Sharp fluorescent lamp (XGA) (1)
TECRA S3 Maintenance Manual (960-532) [CONFIDENTIAL] 4-85