Toshiba TECRA S3 Laptop User Manual


 
Tests and Diagnostics
3-92 [CONFIDENTIAL] TECRA S3 Maintenance Manual (960-532)
Table 3-8 Common error code
Error code Meaning
0x30 BT Control Status should be “Disable”, but it is “Enable”.
0x31 BT Control Status should be “Enable”, but it is “Disable”.
0x32 Power Status should be “OFF”, but it is “ON”.
0x33 Power Status should be “ON”, but it is “OFF”.
0x34 USB I/F Status should be “Attach”, but it is “Detach”.
0x35 USB I/F Status should be “Detach”, but it is “Attach”.
0x36 Wake-up Status should be non-“Assert”, but it is “Assort”.
0x37 Wake-up Status should be “Assert”, but it is non-“Assort”.
0x38 Switch Status should be “OFF”, but it is “ON”.
0x39 Switch Status should be “ON”, but it is “OFF”.
0x3a Module dose not exist.
0x3b Module exists. (not error)
0x3c Command Line is wrong.
0x3d Side band access driver is not resident.
0x3e Bluetooth driver for DOS is not resident.
0x3f Get Status function of Side band access driver is not normal.
0x40 No reply to inquiry
0x41 Device Descriptor can not be acquired. USB I/F is not normal.
0x42 Sideband reset timeout occurs.
0x43 Descriptor type is wrong.
0x44 Descriptor is acquired in spite of Detach condition.
0x45 Configuration file open is not normal.
0x46 Contents of Configuration file are wrong.
0x47 BD_ADDR is wrong (00)
0x48 BD_ADDR is wrong (FF)
0x49 BD_ADDR is wrong (bit0=1)
0x4a BD_ADDR is wrong (bit1=1)
0x4b BD_ADDR is wrong (address defined as an error)
0x4c Suspended during Hard ware switch confirmation.
0x4d RSSI value is less than the standard value.
0x4e Holts
0x4f (reserved)
** Number 0x30 to 0x40 are common error codes of the test program.