Tripp Lite 93-2879 Server User Manual


 
_____________________________________________________________________
B096-016 B096-048 and B092-016 User Manual Page 192
443 stream tcp nowait root sslwrap -cert /etc/config/ssl_cert.pem -key /etc/config/ssl_key.pem
-exec /bin/httpd /home/httpd"
Save the file and signal inetd of the configuration change.
kill -HUP `cat /var/run/inetd.pid`
The HTTPS server should be accessible from a web client at a URL similar to this:
https://<common name of unit>
More detailed documentation about the openssl utility can be found at the website:
http://www.openssl.org/
15.9 Power Strip Control
The Console Server supports a growing list of remote power-control devices (RPCs) which can
be configured using the Management Console as described in Chapter 8. These RPCs are
controlled using the open source NUT and PowerMan tools and the pmpower utility.
PowerMan
PowerMan provides power management in a data center or compute cluster environment. It
performs operations such as power on, power off, and power cycle via remote power controller
(RPC) devices. Target hostnames are mapped to plugs on RPC devices in powerman.conf
powerman - power on/off nodes
Synopsis
powerman [-option] [targets]
pm [-option] [targets]
Options
-1, --on Power ON targets.
-0, --off Power OFF targets.
-c, --cycle Power cycle targets.
-r, --reset Assert hardware reset for targets (if implemented by RPC).
-f, --flash Turn beacon ON for targets (if implemented by RPC).
-u, --unflash Turn beacon OFF for targets (if implemented by RPC).
-l, --list List available targets. If possible, output will be compressed into a host range
(see TARGET SPECIFICATION below).
-q, --query Query plug status of targets. If none specified, query all targets. Status is not
cached; each time this option is used, powermand queries the appropriate RPC's.