Tripp Lite 93-2879 Server User Manual


 
39
4.1.3 SDT Mode
This setting allows port forwarding of LAN protocols such as RDP, VNC, HTPP, HTTPS, SSH and Telnet
through to computers which are connected locally to the Console Server by their serial COM port.
However such port forwarding requires a PPP link to be set up over this serial port.
Refer to Chapter 6.6 - Using SDT Connector to Telnet or SSH connect to devices that are serially attached
to the Console Server for configuration details
4.1.4 Device (RPC, UPS, EMD) Mode
This mode configures the selected serial port to communicate with a serial controlled Uninterruptible
Power Supply (UPS), serial Remote Power Controller/ Power Distribution Unit (RPC) or Environmental
Monitoring Device (EMD)
Select the desired Device Type (UPS, RPC or EMD)
Proceed to the appropriate device configuration page (Serial & Network: UPS Connections, RPC
Connection or Environmental) as detailed in Chapter 8 - Power & Environmental Management)
The B092-016 Console Server also allows you to configure ports as UPS devices that PowerAlert
will manage. PowerAlert will discover the attached UPS device and auto-configure. See
www.tripplite.com/EN/support/PowerAlert/Downloads.cfm for a complete PowerAlert manual.
4.1.5 Terminal Server Mode
Select Terminal Server Mode and the Terminal Type (vt220, vt102, vt100, Linux or ANSI) to
enable a getty on the selected serial port.