Acer Altos G900 Personal Computer User Manual


 
139
FRB-2 Policy Selects an action to implement
when an FRB-2 failure occurs, that
is whether to disable the BSP (Boot
Strap Processor) or not.
An FRB-2 failure occurs if the
system fails to respond after six
minutes of bootup attempt.
Disable FRB2 Timer
Disable BSP
Do not disable BSP
Retry 3 times
Thermal Sensor Specifies whether BIOS will disable
boot when system temperature is
outside the safe range.
Disabled
Enabled
BMC IRQ Specifies the routing address for
the BMC interrupt.
Disabled
5
10
11
Post Error
Pause
When enabled, if the POST finds an
error, it will pause and the user has
to press F1 to continue.
If disabled, even when the POST
finds an error, it will not pause.
This may result to reduced system
functionality.
Disabled
Enabled
AC-Link Sets the AC-Link mode. Last State
Power on
Stay off
Platform Event
Filtering
Specifies whether to enable or
disable the trigger elements for
system sensor events.
Disabled
Enabled
Parameter Description Option
AA G900 ug - EN.book Page 139 Wednesday, September 25, 2002 5:23 PM