Acer Altos G900 Personal Computer User Manual


 
229
0B92: Internal Use Area of BMC
FRU corrupted.
SROM storing chassis
information failed
Available for use except for
FRU command and
emergency management
port function.
0B93: BMC SDR Repository empty. BMC device (chip) failed
0B94: IPMB signal lines do not
respond.
SMC (Satellite Management
Controller) failed
Available for use except for
the access function to SMC
via IPMB.
0B95 BMC FRU device failure. SROM storing chassis
information failed
Available for use except for
FRU command and
emergency management
port function.
0B96 BMC SDR Repository failure. BMC device (chip) failed
0B97 BMC SEL device failure. BMC device (chip) failed
0BB0: SMBIOS - SROM data read
error
SROM data read error
0BB1: SMBIOS - SROM data
checksum bad
Bad checksum of SROM data
0BD0: 1st SMBus device address not
acknowledged.
Some SMBus device (chip)
failed
0BD1: 1st SMBus device Error
detected.
Some SMBus device (chip)
failed
0BD2: 1st SMBus timeout. Some SMBus device (chip)
failed
Expansion ROM not
initialized.
PCI Expansion ROM card not
initialized
Code Error Message Failure Description
AA G900 ug - EN.book Page 229 Wednesday, September 25, 2002 5:23 PM