Avaya 16-601423 Webcam User Manual


 
Configure a Polycom RMX Series Video Conferencing Bridge Platform
Issue 3 January 2008 67
4. Set Carrier Medium to H.323.
5. Set Service Type to tie.
Procedure 3: Add a Signaling Group for the RMX System
To add a signaling group for the RMX system:
1. Use the add signaling-group xx command (where xx is the chosen signaling group) to
access the Signaling Group form.
The Signaling Group form appears.
Figure 13: Example of Page 1 of the Signaling Group Form
2. Set Group Type to h.323.
3. Set IP Video to y.
4. Set Priority Video. If you want all incoming calls to receive priority video transmissions,
select y.
5. Set Trunk Group for Channel Selection to the two-way trunk group you added.
6. Set Near-end Node Name. For example, for an S8300 system, you would enter procr. For
an S8500 or S8700 system, you would enter the name of the CLAN board.