Brother HL-1260 Printer User Manual


 
IV - 5
1.10 Scanner Unit
(1)
Unplug the LD PCB harness (scanner flat cable) connector (6P), and polygon harness
(5P).
(2) Remove the beam from the body by loosening the screws.
(3) Remove the scanner unit from the body by loosening the screws.
Caution: Do not disassemble the scanner unit, it can be only adjusted at the factory.
Left side
Rear
Figure 4.10
Right side
Front
Scanner mount plate
Cartridge stopper assy
C
B
A
Figure 4.9
Cartridge stopper assy
Scanner mount plate
Ground leaf spring
Screws
1.11 Cartridge Stopper Assy
(1)
Loosen 4 screws and remove the scanner mount plate in the direction of the arrow (the
ground leaf spring is also released at the same time.)
(2) Release the hook by bending the arm of the cartridge stopper assy ( A ), slide the
cartridge stopper assy to the left ( B ) and the remove the cartridge stopper assy ( C ).
Figure 4.8
Polygon harness 5P
Screws
Screws
Beam
Scanner unit
Scanner flat cable 6P