Cabletron Systems 8H02-16 Switch User Manual


 
Chapter 6: Local Management
6-40 8H02-16 User’s Guide
The following briefly explains each field of the High Speed Interface
Configuration screen.
Port Type (Read-only)
Displays the name of the interface (FE-100FX or FE-100TX) installed in
ports 15 and 16. Figure 6-13 shows that there is an FE-100TX interface
installed in Port 15 and no interface [N/A] in Port 16.
Link Status (Read-only)
Indicates whether or not there is a physical connection from this port to
another 10BASE-T or 100BASE-TX/FX device. One of the following
values appears:
Link There is a 10BASE-T or 100BASE-TX/FX link signal present;
there is a valid physical connection from this port to another
10BASE-T or 100BASE-TX/FX device.
No Link There is no 10BASE-T or 100BASE-TX/FX link signal
present; there is no valid physical connection from this port to another
10BASE-T or 100BASE-TX/FX device.
Current Operational Mode (Read-only)
This field displays the current operating mode of ports 15 and 16.
Depending on whether a 100Base-FX or 100Base-TX is installed, this
field displays the following:
With a 100Base-FX interface: 100Base-FX or 100Base-FXFD (full
duplex)
With a 100Base-TX interface: Unknown, 10Base-T, 10Base-TFD
(full duplex), 100Base-TX, or 100Base-TXFD (full duplex).
Desired Operational Mode (Selectable)
This field allows the user to select the desired operational mode for an
interface in port 15 or 16. The field toggles between 100Base-FX and
100Base-FXFD (full duplex) when an FE-100FX is installed.
Section 6.14.1 describes how to configure a port with an FE-100FX.