Casio AX200 Network Router User Manual


 
www.axxessid.com
Installation & User Guide
AX200 Installation & User Guide – July 2007
58
Door Release Time
Standard door release time is the amount of time it takes for the door to be locked again, after
being opened by a valid card. (Range: 1•255s)
If the “Extended door open time” option has been activated in the mode settings of a card; then
the door will remain open for the amount of time entered in the Extended field. (Range: 1•255s).
It allows individual cardholders to have the door open for a longer period of time e.g. disabled or
elderly people.
Request to Exit This time can be individually set and is often set longer when the REX is used at
the reception allowing visitors a slightly longer entry time. When the REX Button is used, the
reader fitted outside can be set to sound twice to indicate the door has been released for visitors.
This feature is particularly useful when used with magnet locks since their operation is totally
silent.
Start-up Mode Settings
The start-up mode settings enable you to determine how the door operates in case of total power
failure, including exhaustion of the battery back-up. All the data is stored permanently in the
controller for up to 100 years without the need for any power and upon power-up will continue to
operate without the need for a database download.
High security mode Only cardholders with the high security mode
enabled will have access.
Normal mode Returns to normal mode from whatever the
status was prior to power failure.
Door unlocked The door unlocks permanently until a valid card
with the unlock feature is used twice, or the
door is changed to normal mode from the PC.
Last known mode This will return to the status the door was set to
prior to power failure.
Group(s) contain this point displays the list of the access groups which the current access point
is assigned to.
Door Contact Settings