Casio FX-9750GII Calculator User Manual


 
20051101
12-1
Calling E-CON2 Functions from an eActivity
12
Calling E-CON2 Functions from an eActivity
You can call E-CON2 functions from an eActivity by including an “Econ strip” in the eActivity
file. The following describes each of the four available Econ strips.
uEcon SetupWizard strip
This strip calls the E-CON2 Setup Wizard. The Econ Setup Wizard strip makes it
possible to perform the following series of operations from the eActivity: EA-200
setup using the Setup Wizard R Sampling R Graphing.
uEcon AdvancedSetup strip
This strip calls the E-CON2 Advanced Setup screen. The Advanced Setup provides
access to almost all executable functions (except for the program converter),
including detailed EA-200 setup and sampling execution; graphing and Graph
Analysis Tools; simultaneous sampling with multiple sensors using the
MULTIMETER Mode, etc.
uEcon Sampling strip
This strip records on set of EA-200 setup information configured using Advanced
Setup, and performs sampling. Once setup information is recorded to this type of
strip, sampling starts immediately based on the recorded setup information the next
time the strip is executed.
uEcon Graph strip
This strip graphs sampled data that is recorded in the strip. The sampled data is
recorded to the strip the first time the strip is executed.
This section explains how to insert each type of Econ strip into an eActivity file, and how to
use inserted Econ strips. For details about eActivity operations, see “Chapter 10 eActivity” in
the manual that comes with the fx-9860G SD or fx-9860G.