Installation Sequence Outline
In preparation for using IRC, the following tasks must be performed:
■ Prepare the management console with the necessary hardware and
software for out-of-band communication
■ Prepare the managed server for out-of-band communications by
installing a modem or connecting the managed server to a suitable
communications device
■ Configure the usage and communication parameters of IRC
■ Set up a list of authorized users and their permissions in the IRC user
database
figure2.EPS
CSR TSR CSR CSR
TSR CSR CSR
CSR
CSR TSR CSR CSR
TSR CSR CSR
CSR
Figure 1-1. Communication topology showing a modem-based out-of-band connection between a
managed server, left, and a management console, right