Compaq 281862-002 Personal Computer User Manual


 
C-5
Compaq Integrated Remote Console User Guide
Writer: Caroline Juszczak Project: Compaq Integrated Remote Console User Guide Comments: 281862-002
File Name: L-APPC.DOC Last Saved On: 12/21/98 11:11 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
If you are using Compaq Insight Manager as the terminal application
and have either a Compaq SpeedPaq 33.6 or U.S. Robotics modem
installed in the management console, change the “initialize” string under
Insight Manager’s COM port setup from “AT&F&C1&D2E0S0=0” to
“AT&F1&C1&D2&B1E0S0=0”. This selects the hardware-flow control
template and also specifies a fixed DTE baud rate.
If you have either a Compaq SpeedPaq 33.6 or U.S. Robotics modem in
the managed server, make sure that &B1 is included in either the
primary or secondary initialization string. If this type of modem is used
in the management console, make sure that the initialization string used
by your communications package includes &B1. See chapter 2 for
information on correctly configuring the management console.
Double check the primary and secondary modem initialization strings
with the requirements specified in Chapter 2. Check Appendix A for the
appropriation initialization strings for your modem.
If you are using HyperTerminal to establish the connection, make sure
that your IRC firmware is 1.41 or greater. Obtain the latest system ROM
upgrade for your server to upgrade the Integrated Remote Console
firmware.
Try the connection again following a cold power-cycle of the managed
server. If problem only occurs after the server is warm-booted, obtain
the latest system ROM upgrade for your server. IRC firmware versions
1.51 and greater fix a problem where IRC is unavailable following a
warm boot.