E-4
Error Codes
Writer: M. Church Project: Compaq Professional Workstation AP200 Reference Guide Comments: 352620-003
File Name: L-APPE.DOC Last Saved On: 12/14/98 2:40 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Power-On Self Test Message
Continued
Message Beeps* Probable Cause Recommended Action
201-Memory Error None RAM failure
1. Make sure your
memory module(s)
(if any) are installed
properly.
2. Replace the
memory module(s).
3. Replace the system
board.
203-Memory Address
Error
None RAM failure
1. Make sure your
memory module(s)
2. Replace the
memory module(s).
3. Replace the system
board.
207-ECC Corrected
Single Bit Errors in
DIMM/SIMM Pair(s) X,
X, ...
2S Single Bit ECC error Replace DIMM if error
persists.
213-Incompatible
DIMM Module in
DIMM Socket(s) X, X,
...
2S A DIMM module in DIMM
socket identified in the error
message is missing critical
SPD information, or it is
incompatible with the chipset.
Replace the DIMM with a
module conforming to
the SPD standard. See
Chapter 4, “Hardware
Upgrades.”
* L = Long, S = Short
Continued