Operation, cont’d
Fiber Matrix 6400 Switcher • Operation
3-24
Example 9: Muting and unmuting an output
In the following example, several switcher outputs are muted and unmuted. The
steps show the front panel indications that result from your action.
1. Clear all selections: Press and release the Esc button.
C O N T R O L
PRESET
ENTER
ESCVIEW
Press the Esc button to clear all selections.
The button flashes once.
2. Select View-only mode: Press and release the View button to enter View-only
mode. The View button lights red.
C O N T R O L
PRESET
ENTER
ESCVIEW
1 2 3 4 5 6 7 8 15 16
17 18 19 20 21 22 23 24 31 32
OUTPUTS
Until you select an input, only the buttons for untied outputs light.
Press the View button.
The button lights.
3. Mute the outputs: One at a time, press and hold the Output 3 button and
then the Output 4 button for approximately 2 seconds until each button
begins to blink. The output 3 and output 4 signals are muted.
3
4
3
4
The button blinks
to indicate that the
outputs are muted.
The button blinks
to indicate that the
outputs are muted.
Mute outputs one at a time.
2 seconds
2 seconds
Press and hold the Output 3 button.
Press and hold the Output 4 button.