4-15
Fiber Matrix 6400 Switcher • Programmer’s Guide
Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Resets
Reset global presets and
names
E
ZG
}
Zpg
]
Clear all global presets and
their names.
Reset one global preset
EX&
ZG
}
Zpg
X&]
Clear global preset
X&
.
Reset all mutes
E
ZZ
}
Zpz
]
Unmute all outputs.
Reset room map
E
ZR
}
Zpr
]
Clear all room definitions.
Reset individual room
EX*
ZR
}
Zpr
X*]
Delete room
X*
.
Reset individual room
preset
EX*
*
X(
ZP
}
Zpp
X*
*
X(]
Clear an individual room
preset and name.
Reset flash
E
ZFFF
}
Zpf
]
Reset flash memory (erase all
user-supplied files).
Reset whole switcher
(Mode 5 reset)
E
ZXXX
}
Zpx
]
Clear all ties and presets.
Absolute reset
E
ZQQQ
}
Zpq
]
Similar to Reset whole
switcher, plus clear the IP
address to 192.168.254.254
and subnet mask to
255.255.000.000.
Erase user-supplied Web
pages/files
E
filenameEF
}
Delfilename
]
Information requests
Information request I
V
X1$
X
X1%
•A
X1$
X
X1%
•S
X1^
1
X1^
2
...
X1^
8
]
V
X1$
X
X1%
shows the
number of available
inputs and outputs for this
configuration.
A
X1$
X
X1%
has no meaning
for this product.
S
X1^
1
X1^
2
...
X1^
8
shows the
board type installed in each
slot.
Slot/plane/LC information
0*
X1&
I
X1*
a
X1*
b
X1*
c
X1*
d
X1*
e
X1*
f
X1*
g
X1*
h
]
Request part number N
60-878-01
]
See appendix A for part
numbers.
N
There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which
is the overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest
optional Extron firmware update, which is available at www.extron.com.
Query firmware version Q
X2)]
Example:
Q
1.23
]
The factory-installed
controller firmware version
is 1.23 (sample value only).
N
X&
= Global preset # 00 – 32 (00 = current configuration)
X*
= Room # (for room presets) 10 max. (Each can have up to 10 presets (
X(
s) assigned.)
X(
= Room preset # 00 – 10 (00 = current configuration for room)
X1$
= Number (quatity) of inputs 8, 16, 24, 32, 40, 48, 56, or 64
X1%
= Number (quatity) of outputs 8, 16, 24, 32, 40, 48, 56, or 64
X1^
= Board installed 0 = No board installed, 1 = 8x8 multimode board,
2 = 8x8 singlemode board, 3 = SDI/HD-SDI board,
x = unknown board or mix of transceivers installed
X1&
= I/O board slot number 1 – 8
X1*
= Fiber optic transceiver module installed 0 = no module installed, 1 = multimode, 2 = singlemode
X1(
= Part number 68-878-01
X2)
= Firmware version number to second decimal place (x.xx)