Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Save, recall, and directly write presets
N
•Ifyoutrytorecallapresetthatisnotsaved,thematrixswitcherrespondswiththeerrorcodeE11.
If a room is not defined (does not exist in the switcher), the matrix switcher responds with the error code E21.
The following characters are invalid in preset names: + - , ` @ = [ ] { } ‘ “ ; : | \ and ?.
Save current configuration
as a global preset
X&
,
Spr
X&]
Command character is a
comma.
Example:
9
,
Spr9
]
Save current ties as preset 9.
Recall a global preset
X&
.
Rpr
X&]
Command character is a
period.
Example:
5
.
Rpr05
]
Recall preset 5, which
becomes the current
configuration.
Save current ties as a room
preset
X*
*
X(
,
Rmm
X*•
Spr
X(]
Command character is a
comma.
Example:
3*9,
Rmm03
Spr09
]
Save current ties as preset 9
for room 3.
Direct write process —
N
The direct write of a global preset should always be preceded by a clear global preset ties command of that same
preset number, as shown below. In a directly-written preset, each output position’s tied input (or no tied input) remains
unchanged unless overwritten or cleared.
If you do not clear the ties in a global preset number before you directly write a global preset to that number, ties that
are part of the previous version of the specified preset with the same number can unexpectedly become part of the newly-
created preset.
Clear a global preset’s ties
E
+
X&
P0*!
}
Spr
X&]
Clear all ties in preset
X&
.
Directly write a global preset
E
+
X&
P
X@
*
X#
!
X@
*
X#
%
X@
*
X#
$ ...
X@
*
X#
%
}
Enter as many ties as are
valid for this configuration.
The ! tie command, & tie,
and % tie commands are all
valid.
Spr
X&]
Example:
E
+27P0*!
}
Spr27
]
Clear all ties in preset 27.
+27P12*5!10*09%3*2!3*8&
Esc
Brackets are shown to separate
ties for clarity only. Create
global preset 27, which ties
input 12 to output 5, input 10
to output 9, input 3 to output
2, and input 3 to output 8.
Spr27
]
Write room outputs
EX*
,
X#
1
,
X#
2
, ...
X#
n
MR
}
See notes.
Mpr
X*
,
X#
1
,
X#
2
, ...
X#
n
]
N
•Aroomcancontainamaximumof16outputs.
An output can belong to only one room.
The maximum number of rooms (
X*
) is 10.
If no room name is assigned, the default name is “Room #
X*
X#
1
,•
X#
2
,•
X#
3
”.
Example:
E
8,3,04,5,6MR
}
Mpr8,03,04,05,06
]
Outputs 3, 4, 5, and 6 are
assigned to room 8.
N
X&
= Global preset # 00 – 32 (00 = current configuration)
X*
= Room # (for room presets) 10 max. (Each can have up to 10 presets (
X(
) assigned.)
X(
= Room preset # 00 – 10 (00 = current configuration for room)
X@
= Input number 00 – 64 (00 = untied)
X#
= Output number 01 – 64