Extron electronic 6400s Switch User Manual


 
3-29
Fiber Matrix 6400 Switcher • Operation
Performing soft system resets (resets 3, 4, and 5)
Perform a soft reset of the switcher as follows:
1. Use an Extron Tweeker or other small screwdriver to press and hold the rear
panel Reset button until the rear panel Reset LED and the front panel View
and Esc buttons blink once (events reset), twice (system reset), or three times
(absolute reset).
Release, then immediately
press and release again.
RESET
RESET
RESET
CONTROL
T
VIEW
ESC
CONTROL
T
VIEW
ESC
CONTROL
T
VIEW
ESC
Release, then immediately
press and release again.
6 seconds
9 seconds
Press and hold
the Reset button.
3 seconds
View and Esc buttons flash once.
Reset LED flashes once.
Release, then immediately
press and release again.
Reset LED flashes twice.
Press and hold
the Reset button.
Press and hold
the Reset button.
Reset LED flashes
three times.
View and Esc buttons flash twice.
View and Esc buttons flash three times.
IP Settings
Reset
Absolute
Reset
Events
Reset
2. Release the Reset button and then immediately press and release the Reset
button again. Nothing happens if the second momentary press does not occur
within 1 second.