Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Names
Write global preset name
EX&
,
X1)
NG
}
Nmg
X&
,
X1)]
Example:
E
1,Security 1NG
}
Nmg01,Security 1
]
Name global preset 1
“Security 1”.
Read global preset name
EX&
NG
} X1)]
Example:
E
2NG
}
Security 2
]
Global preset 2 is named
“Security 2”.
Write room name
EX*
,
X1)
NR
}
Nmr
X*
,
X1)]
Example:
E
1,Classrm 1NR
}
Nmr01,Classrm 1
]
Name room 1 “Classrm 1”.
Read room name
EX*
NR
} X1)]
Write room preset name
EX*
*
X(
,
X1)
NP
}
Nmp
X*
*
X(
,
X1)]
Example:
E
1*3,Podium_DVDNP
}
Nmp01*3,Podium_DVD
]
Name room1, preset 3
“Podium_DVD”.
Read room preset name
EX*
,
X(
NP
}
X1)]
N
•Donotuseleadingspacesinpresetnames.
If a preset is unassigned, the
X1)
displays [unassigned].
If a global preset is saved, but not yet named, the default name is Preset
X&
.
If a room preset is saved, but not yet named, the default name is Rm
X*
Prst
X(
.
Write input name
EX!
,
X1)
NI
}
Nmi
X!
,
X1)]
Example:
E
1,Podium camNI
}
Nmi01,Podium cam
]
Name input 1 “Podium cam”.
Read input name
EX!
NI
} X1)]
Write output name
EX#
,
X1)
NO
}
Nmo
X#
,
X1)]
Example:
E
1,Main PJ1NO
}
Nmo01,Main PJ1
]
Name output 1 “Main PJ1”.
Read output name
EX#
NO
} X1)]
Front panel lockout (Executive mode)
Lock front panel 1X
Exe1
]
Enable executive mode.
Unlock front panel 0X
Exe0
]
Disable executive mode.
View lock status X
X1#]
N
X&
= Global preset # 00 – 32 (00 = current configuration)
X1)
= Name 12 characters maximum for global and room preset names
11 characters maximum for room names
X*
= Room # (for room presets) 10 max. (Each can have up to 10 presets (
X(
) assigned.)
X(
= Room preset # 00 - 10 (00 = current configuration for room)
X!
= Input number 01 – 64
X#
= Output number 01 – 64
X1#
= Lock mode 0 = unlocked
1 = locked