Extron electronic DVS 304 Network Card User Manual


 
f. Click the Take button to tie the DVS 304’s input to the selected switcher
output. The program creates a custom script that is then be loaded onto
the DVS 304. The Status box updates with the status of the script on
the DVS 304, showing if the DVS 304’s script is connected to the matrix
switcher, and showing the current tie associated with the selected output.
Using the DVS and Matrix Switcher After the DVS is Synchronized to the
Matrix Switcher
After completing step 4, above, ensure the following is done when using the DVS with the
matrix:
Perform all input switching using the matrix switcher. A 1-second RGB delay on the
matrix is recommended to minimize the appearance of a glitch in the output while the
DVS locks onto the new signal.
The DVS senses when the matrix switcher changes input ties, and the DVS recalls the
matching input preset, so input presets need not be recalled manually.
The DVS 304 and the matrix switcher must remain on the same subnet. Do not
change the matrix switcher’s IP address. If the IP address of the matrix is altered,
repeat step 4 above.
Removing the Sync to Matrix Script
If the Sync to Matrix feature is no longer being used, the script can be removed from the
DVS by the following steps:
1. Open the Signal Processing Products Control Program and connect to the DVS via IP
(not RS-232).
2. Under the Tools menu, select Sync DVS 304 to Matrix Switcher... . The
Sync DVS 304 to Matrix Switcher window opens.
3. Click Remove Script.
DVS 304 Series • Operation 28