Extron electronic DVS 304 Network Card User Manual


 
Command ASCII (Telnet)
(host to processor)
URL Encoded (Web)
(host to processor)
Response
(processor to host)
Additional description
Set unit name to factory
default
24
E • CN } W%20CN| Ipn • X4( ] X4( is the name the processor was shipped
with: DVS304-##-##-##, a combination of
the model name and the last 3 pairs of hex
numbers in the processor’s MAC address
(for example, DVS304-00-02-3d).
Read unit name
E CN } WCN| X1@ ] X1@ is the processor’s current unit name.
X4( is its factory default name.
Set time/date
24
E X1#CT } W X1# CT| Ipt • X1# ] X1# is local date and time format. The set
format is MM/DD/YY-HH:MM:SS.
Example: 11/18/03-10:54:00
Read time/date
E CT } WCT| X1# ]
The Read format is day of week DD month year
HH:MM:SS.
Example: Tue, 18 Nov 2008 18:19:33.
Set GMT offset
24
E X#CZ} W X#CZ
|
Ipz X# ]
Set the Greenwich Mean Time GMT) offset
value (X#) for the processor’s location.
GMT offset (-12.00 to +14.00) represents the
time difference in hours and minutes
(± hh:mm relative to Greenwich, England.
The plus sign and leading zero are optional.
Example: 5:30 = +05:30.
Read GMT offset
ECZ } E
WCZ
|
X% ]
Set daylight saving time
24
E X3$CX} WX3$CX
|
IpxX3$ ] X3$ is the daylight savings time of day.
Daylight savings time (DST) is a 1-hour offset
that is observed in the USA and parts of
Europe and Brazil.
Read daylight saving time
ECX }
WCX
|
X3$ ]
Set DHCP on
24
E1DH }
W1DH
|
Idh1 ]
Set DHCP off
24
E0DH }
W0DH
|
Idh0 ]
View DHCP mode
EDH }
WDH
|
IdhX% ] X% = 0 (off) or 1 (on).
NOTE: X# = Greenwich Mean Time (GMT) offset value (-12:00 to 14:00) in hours and minutes (hh:mm)
X% = On/Off 0 = off/disable, 1 = on/enable
X1@ = Name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and the minus sign/hyphen (-). First character must be an alpha character. Last character
must not be a minus. No blank or space characters are permitted, and no distinction is made between upper and lowercase.
X1# = Local date and time format Set format (MM/DD/YY-HH:MM:SS); for example, 06/21/02-10:54:00. Read format (day of week, date month year (HH:MM:SS)),
for example, Thu, 20 Feb 2003 18:19:33
X3$ = Daylight saving time (used in the northern hemisphere [USA] and parts of Europe and Brazil) 0 = off/ignore, 1 = on, 2 = Europe, 3 = Brazil
X4( = Default name: a combination of the model name and the last 3 character pairs of the unit’s MAC address (for example, DVS-304-00-023D)
DVS 304 Series • SIS Communication and Control 48