Extron electronic DVS 304 Network Card User Manual


 
Command ASCII (Telnet)
(host to processor)
URL Encoded (Web)
(host to processor)
Response
(processor to host)
Additional description
Set IP address
24
E X1$CI } WX1$CI
|
Ipi • X1$ ] X1$ = IP address (xxx.xxx.xxx.xxx).
Leading zeros in each of the four fields are
optional in setting values.
Read IP address
24
ECI }
WCI
|
X1$]
Leading zeros in each of the four fields are
suppressed in returned values.
Read hardware
address (MAC)
ECH }
WCH
|
X1*] X1* = hardware media access control (MAC)
address (xx-xx-xx-xx-xx-xx).
Set subnet mask
24
E X1(CS} WX1(CS
|
Ips•X1( ] X1( is the subnet mask (xxx.xxx.xxx.xxx).
Syntax is the same as for the IP addresses.
Leading zeros are optional in setting values.
Read subnet mask
ECS} E WCS
|
X1( ]
Leading zeros are suppressed.
Set gateway IP address
24
E X1$CG} W X1$CG
|
Ipg•X1$ ] X1$ is the IP address. Leading zeros are
optional.
Read gateway IP address
ECG} WCG
|
X1$ ]
Set broadcast mode
E X6$,X1$EB} W X6$%2C X1$EB
|
BmdX6$, X1$ ]
Set administrator password
24
E X3#CA} WX3#CA
|
Ipa•X3# ]
Set the administrator access password.
(X3# is 4-12 alphanumeric characters)
The password is case sensitive. Special
characters (spaces or symbols) are
not allowed.
Clear administrator
password
24
E•CA}
W%20CA
|
Ipa• ]
Clear/remove all passwords (administrator
and user)
NOTE: A user password cannot be assigned if an administrator password does not exist. Entering a password when the DVS 304 has not been congured yields an
E14 response from the processor. If the administrator password is cleared (removed), the user password is also removed.
Read administrator password
ECA} WCA
|
X3# ]
NOTE: X% = On/Off 0 = off/disable, 1 = on/enable
X1$ = IP address (xxx.xxx.xxx.xxx); leading zeros in each of 4 elds are optional in setting values, and are suppressed in returned values.
X1* = Hardware (MAC) address (xx-xx-xx-xx-xxxx)
X1( = Subnet mask (xxx.xxx.xxx.xxx). Leading zeros are optional in setting values in each of four fields, and are suppressed in returned values.
X3# = Password (12 characters = maximum length; no special characters are allowed).
X6$ = Broadcast repetition rate in seconds (0 – 255 max; default = 0 = clear). The response is returned with leading zeros. 1 – 11 = entry without password goes to the level
specified (if an admin password exists). The response as returned as 2-digits with a leading zero.
DVS 304 Series • SIS Communication and Control 49