Extron electronic MAV PLUS SERIES Switch User Manual


 
Programmer’s Guide, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide
4-16
Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Digital Sync Validation Processing (DSVP)
View DSVP
(individual sync frequency)
X$
LS
X1$
,
X1$]
Listed as horizontal
frequency, vertical frequency.
Example:
2LS
031.5,060.00
]
Input 2 frequency is
31.5 kHz (horizontal) and
60 Hz (vertical).
N
The matrix switcher returns 000.00,000.00 if there is no connection or if sync frequencies are not applicable.
View connections 0LS
X1%
1
X1%
2
X1%
3
...
X1%
n
]
Each
X1%
response is
the connection status
(0 = no input detected,
1 = input detected) of
an input, starting from input 1.
n is the maximum number of
inputs for this model.
RGB delay (CrossPoint)
Set RGB delay
EX@
*
X1^
D
}
Out
X@
•Dly
X1^
*1
]
Example:
E
13*7D
}
Out13•Dly07
]
Set the RGB interval for ties
to output 13 to 3.5 seconds
(7 x 0.5 sec.).
View RGB delay
EX@
D
} X1^]
Example:
E
14D
}
05
]
Output 14 interval is
2.5 seconds (5 x 0.5 sec.).
I/O Grouping
N
The group that is assigned in each of the following I/O grouping commands (
X1&
) must be 1, 2, 3, 4, or 0 (not grouped).
Write input grouping
EX1&
1
X1&
2
...
X1&
n
I
}
Gri
X1&
1
X1&
2
X1&
3
...
X1&
n
]
Each
X1&
entry is the group
number assigned to an
input position, starting from
input 1. n is the highest-
numbered input for this
model.
Example:
MAV Plus 3264
E
40133000044...4I
}
See below.
01 Input:
GriResponse #s = group:
Input 1 in group 4
02 03 04 05 06 07 08 09 10 11 12
4 0 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3
13 14 15 16 17 18 19 20 21 22 23 24
Input 2 not grouped
2 1 2 2 3 3 3 3
25 26 27 28 29 30 31 32
Input 32 in group 3
Input 1 - Group 4, Input 2 -
Group 0 (not grouped), ...
Input 32 - Group 4.
N
If verbose mode is off (see the "Set verbose mode" SIS command on page 4-23), the Gri preface is omitted in the response.
Write output grouping
EX1&
1
X1&
2
...
X1&
n
O
}
Gro
X1&
1
X1&
2
X1&
3
...
X1&
n
]
Each
X1&
entry is the group
number assigned to an output
position, starting from output 1.
n is the highest-numbered
output for this model.
N
If verbose mode is off (see the "Set verbose mode" SIS command on page 4-23), the Gro preface is omitted in the response.
N
X@
= Output number 01 – (maximum number of outputs for your model)
X$
= Input number 01 – (maximum number of inputs for your model)
X1$
= Sync frequency xxx.xx (frequency in Hz [V] or kHz [H])
X1%
= Signal detection 0 = no input detected 1 = input detected
X1^
= RGB delay interval Delay in ½ second increments (10 maximum)
X1&
= Group # (for I/O grouping) 1 – 4 (0 = no group)